Borehole Geophysical Logging Systems, Probes, Camera Sondes and  Winches
for ground water, the environment, minining, geotechnical investigations and exploration
 

 

Flowmeter Sondes
The Geovista flowmeter probes can be used on their own or in combination with other Geovista sondes

Impeller Flowmeter: Different size impeller cages can be interchanged to suit different pipe or borehole diameters.

Specifications:
Weight / length: 3.5kg / 0.48m
Cage Diameter: Optional interchangeable impeller cage sizes to order.
Typically: 50, 70 and 100mm
Threshold Velocity: Varies with cage size. (Typically 1 m/min with 50 mm cage)
Resolution: 1/40th turn
Data output Flow rate, direction
Max. Pressure: 20MPa
Max. Temp.: 80ºC


Heat-Pulse Flowmeter: This sonde is used for applications where the flow rate is below the threshold of the impeller

Specifications:
Weight / length: 6.2kg / 0.9m
Sonde Diameter: 51 mm
Measuring range: 0.1 to 3 m/min
Resolution: 0.1s
Data output Time, Direction
Max. Pressure: 20MPa
Max. Temp.: 80ºC

Fluid Sampler Sonde
The Geovista Fluid Sampler is capable of retrieving both gas and liquid samples at downhole pressure conditions. A variation that is suitable for sampling dissolved trace gasses includes a downhole circulating micro-pump to avoid sample contamination.

The probe can also be fitted with a water level indicator. Further correlation can be established by combining the sampler with other Geovista sondes like a Gamma Ray and / or a CCL sonde.

Specifications:
Weight: 3.0 kg
Length: 0.45 m
Diameter: 44 mm
Sample Volume: 1/3, 1/4, 1/2, 1, 1.5 and 2 Litre to order
Max. Pressure: 20MPa
Max. Temp.: 80ºC

 

 

Web Hosting and Design by LiveTech